SPECIFICATIONS
- Height Maximum 4869 mm192 in
- Length Maximum 11419 mm450 in
- Width Maximum 2639 mm104 in
- Voltage 3-13.8 kV
- Aspiration Turbocharged-aftercooled
- Bore 320 mm12.6 in
- Stroke 480 mm18.9 in
- Genset Rating Range 2780 - 4170 kWe
- Configuration 6,8,9 cylinder
- Engine Type 4-stroke-engine
- Fuel Type Diesel oil / heavy fuel oil (HFO) / crude oil
- Emission Level Up To World bank emission certification (Stage 2)
- Engine Efficiency Up To 46.00%
- Frequency At Speed 50 Hz @ 600 / 60 Hz @ 600
- Normal Ramp Up To 100 Load 85 s
- Engine Rating Range 2880 - 4320 kW
- Specific Fuel Oil Consumption Wb I Up To 178 g/kWh0.392 Ib/kWh
- Specific Fuel Oil Consumption Wb Ii Up To 177 g/kWh0.39 Ib/kWh
- Specific Lube Oil Consumption 0.6 g/kWh0.001 Ib/kWh
- Emergency Ramp Up 10 To 100 Load 30 s
- Ready To Accept Loads Preheated Vented 40 s
- Mean Effective Pressure Up To 24.9 bar361 psi
- Swept Volume 38.6 l/cyl2356 in³
- Length Minimum 9302 mm366 in
- Width Minimum 2600 mm102 in
- Height Minimum 4801 mm189 in
- Dry Weight Genset Maximum 98 ton (US)216053 lb
- Dry Weight Genset Minimum 73 ton (US)160937 lb
- Industry power-generation-diesel-hfo
EQUIPMENT
CM32C Inline Standard Equipment
- Fuel System
- Circulation module
- Pre-pressure module
- Separator module
- Engine ventilation module (only dual fuel (DF) and gas)
- Gas valve unit (GVU) (only dual fuel (DF) and gas)
- Ignition fuel oil module (only dual fuel (DF))
- Lubricating Oil System
- Combined module: cooling water system and lube oil system
- Lube oil separator module
- Piping interface module
- Cooling Water System
- Combined module: see lube oil system
- Cooling water system with radiators
- Piping interface module
- Starting System
- Starting air compressor module
- Starting air receiver module
- Combustion Air System
- Air filter - pocket
- Air filter - oil bath
- Air filter - pulse
- Exhaust System
- Exhaust gas silencer
- Selective catalytic reduction (SCR) system
- Oxidation catalytic (Oxicat) converter system
- Exhaust gas ventilation module (only dual fuel (DF) and gas)
- Control & Monitoring System
- Local control panel (LCP)
- Local data panel (LDP) / generator control panel (GCP)
- Motor control center module (MCC)
- Engine monitoring package
- Gas leak detection per cylinder (only dual fuel (DF) and gas)
- Mounting System
- Elastic mounting - genset/engine
RELATED PRODUCTS
3412C (50 Hz)
power generation diesel hfo
- Height Maximum: 1906 mm75 in
- Length Maximum: 162.4 mm4135 in
- Width Maximum: 1989 mm78.3 in
3512A (50 Hz)
power generation diesel hfo
- Minimum Rating: 1000 kVA
- Maximum Rating: 1400 kVA
- Voltage: 220 to 13800 Volts
3512B (50 Hz)
power generation diesel hfo
- Height Maximum: 2367 mm93.2 in
- Length Maximum: 5637 mm221.9 in
- Width Maximum: 2286 mm90 in
3516 (50 Hz)
power generation diesel hfo
- Height Maximum: 2367 mm93.2 in
- Length Maximum: 5919 mm232.9 in
- Width Maximum: 2286 mm90 in
3516B (50 Hz)
power generation diesel hfo
- Height Maximum: 2367 mm93.2 in
- Length Maximum: 5928 mm233.4 in
- Width Maximum: 2286 mm90 in
3516B DGB™ (50 Hz)
power generation diesel hfo
- Minimum Rating: 1750 kVA
- Maximum Rating: 2275 kVA
- Voltage: 220 to 11000
3516E (50 Hz)
power generation diesel hfo
- Height Maximum: 3476 mm136.9 in
- Length Maximum: 9195 mm362 in
- Width Maximum: 2552 mm100.5 in
C1.5 (50 Hz)
power generation diesel hfo
- Height Maximum: 1054 mm41.5 in
- Length Maximum: 1400 mm55.1 in
- Width Maximum: 620 mm24.4 in
C2.2 (50 Hz)
power generation diesel hfo
- Height Maximum: 1115 mm43.9 in
- Length Maximum: 1500 mm59.1 in
- Width Maximum: 620 mm24.4 in