C1.5 (50 Hz) power generation diesel hf

  • Height Maximum 1054 mm41.5 in
  • Length Maximum 1400 mm55.1 in
  • Width Maximum 620 mm24.4 in

SPECIFICATIONS

  • Height Maximum 1054 mm41.5 in
  • Length Maximum 1400 mm55.1 in
  • Width Maximum 620 mm24.4 in
  • Minimum Rating 10.0 kVA
  • Maximum Rating 13.5 kVA
  • Voltage 110 to 415 Volts
  • Frequency 50 Hz
  • Speed 1500 rpm
  • Emissions Fuel Strategy EU Stage IIIA
  • Engine Model Cat® C1.5
  • Compression Ratio 22.5:1
  • Governor Type Mechanical
  • Fuel System Indirect Injection
  • Bore 84 mm3.3 in
  • Displacement 1.5 l91.3 in³
  • Stroke 90 mm3.5 in
  • Industry power-generation-diesel-hfo

EQUIPMENT

C1.5 (50 Hz) Standard Equipment

  • Air Inlet System
    • Air cleaner; light duty with disposable element
  • Control Panel
    • EMCP 4.1
  • Cooling System
    • Radiator and cooling fan with guards
    • Coolant drain line with valve
    • Fan drive, battery charging alternator drive
    • Caterpillar extended life coolant
  • Exhaust System
    • Stub pipe, gaskets, raincap & SAE exhaust flange for customer use; shipped loose
  • Fuel System
    • Standard open set fuel tank / base supplied
    • Base, formed steel with single wall integral 8-hour fuel tank
  • Generators and Generator Attachments
    • 12 leads
    • IP23 Protection
    • Voltage regulator (single phase sensing)
    • Tower panel, IP22, bottom cable entry
    • Segregated low voltage (AC/DC) wiring panel
    • Circuit breaker, IEC, 3 pole, mounted in tower panel
  • Governing System
    • Mechanical governing system
  • Lube System
    • Lubricating oil
    • Oil drain line with valve
  • Mounting System
    • Captive linear vibration isolators between base and engine-generator
    • Includes lifting provisions and termination points for coolant
  • Starting / Charging System
    • 12 Volt battery with rack and cables
  • General
    • Engine and alternator pre-paint, Caterpillar yellow

C1.5 (50 Hz) Optional Equipment

  • Alternator Options
    • Coastal insulation protection
  • Certificates
    • Global certification for CIS
    • European upgrade to STD set for CE certificate
  • Circuit Breakers
    • 4 Pole circuit breaker
    • Pad-locable breaker device
  • Control Panel Options
    • EMCP 4.2
    • Volt free contacts for common alarm
    • Volt free contacts for genset running
    • Battery charger
    • Emergency stop with key
  • Cooling System
    • Coolant heater
  • Enclosures
    • Sound attenuated enclosure (GALV)
    • Single point lift for enclosure
  • Fuel System
    • Skidbase for open sets
    • Skidbase for Enclosures
    • DEFRA bunded fuel tank
    • Low fuel level alarm
    • Fuel transfer control
    • 1000 hr extended service interval
    • Base feet
  • Mounting Options
    • Battery removal
    • Industrial silencer removal
    • Silencer installation kit
  • Special Test and Inspection
    • PGS test report @ 1.0 power factor
  • General
    • Radiator Stone Guard
    • Packing Case - compact set
    • Packing case - canopied set

360° INTERACTIVE

Exterior

Interior

RELATED PRODUCTS

3412C (50 Hz) - Power-generation-diesel-hfo

3412C (50 Hz)

power generation diesel hfo

  • Height Maximum: 1906 mm75 in
  • Length Maximum: 162.4 mm4135 in
  • Width Maximum: 1989 mm78.3 in
Get a quote
3512A (50 Hz) - Power-generation-diesel-hfo

3512A (50 Hz)

power generation diesel hfo

  • Minimum Rating: 1000 kVA
  • Maximum Rating: 1400 kVA
  • Voltage: 220 to 13800 Volts
Get a quote
3512B (50 Hz) - Power-generation-diesel-hfo

3512B (50 Hz)

power generation diesel hfo

  • Height Maximum: 2367 mm93.2 in
  • Length Maximum: 5637 mm221.9 in
  • Width Maximum: 2286 mm90 in
Get a quote
3516 (50 Hz) - Power-generation-diesel-hfo

3516 (50 Hz)

power generation diesel hfo

  • Height Maximum: 2367 mm93.2 in
  • Length Maximum: 5919 mm232.9 in
  • Width Maximum: 2286 mm90 in
Get a quote
3516B (50 Hz) - Power-generation-diesel-hfo

3516B (50 Hz)

power generation diesel hfo

  • Height Maximum: 2367 mm93.2 in
  • Length Maximum: 5928 mm233.4 in
  • Width Maximum: 2286 mm90 in
Get a quote
3516B DGB™ (50 Hz) - Power-generation-diesel-hfo

3516B DGB™ (50 Hz)

power generation diesel hfo

  • Minimum Rating: 1750 kVA
  • Maximum Rating: 2275 kVA
  • Voltage: 220 to 11000
Get a quote
3516E (50 Hz) - Power-generation-diesel-hfo

3516E (50 Hz)

power generation diesel hfo

  • Height Maximum: 3476 mm136.9 in
  • Length Maximum: 9195 mm362 in
  • Width Maximum: 2552 mm100.5 in
Get a quote
C1.5 (50 Hz) - Power-generation-diesel-hfo

C1.5 (50 Hz)

power generation diesel hfo

  • Height Maximum: 1054 mm41.5 in
  • Length Maximum: 1400 mm55.1 in
  • Width Maximum: 620 mm24.4 in
Get a quote
C2.2 (50 Hz) - Power-generation-diesel-hfo

C2.2 (50 Hz)

power generation diesel hfo

  • Height Maximum: 1115 mm43.9 in
  • Length Maximum: 1500 mm59.1 in
  • Width Maximum: 620 mm24.4 in
Get a quote