SPECIFICATIONS
- Height Maximum 1115 mm43.9 in
- Length Maximum 1500 mm59.1 in
- Width Maximum 620 mm24.4 in
- Minimum Rating 13.0 kVA
- Maximum Rating 22.0 kVA
- Voltage 110 to 415 Volts
- Frequency 50 Hz
- Speed 1500 rpm
- Emissions Fuel Strategy EU Stage IIIA
- Engine Model Cat® C2.2, In-line 4, 4-cycle diesel
- Compression Ratio 22.5:1
- Governor Type Mechanical
- Fuel System Indirect Injection
- Bore 84 mm3.3 in
- Displacement 2.2 l135.2 in³
- Stroke 100 mm3.9 in
- Industry power-generation-diesel-hfo
EQUIPMENT
C2.2 (50 Hz) Standard Equipment
- Air Inlet System
- Air cleaner; light duty with disposable element
- Control Panel
- EMCP 4.1
- Cooling System
- Radiator and cooling fan with guards
- Coolant drain line with valve
- Fan drive, battery charging alternator drive
- Caterpillar extended life coolant
- Exhaust System
- Stub pipe, gaskets, raincap & SAE exhaust flange for customer use; shipped loose
- Fuel System
- Standard open set fuel tank / base supplied
- Base, formed steel with single wall integral 8-hour fuel tank
- Generators and Generator Attachments
- 12 leads
- IP23 Protection
- Voltage regulator (single phase sensing)
- Tower panel, IP22, bottom cable entry
- Segregated low voltage (AC/DC) wiring panel
- Circuit breaker, IEC, 3 pole, mounted in tower panel
- Governing System
- Mechanical governing system
- Lube System
- Lubricating oil
- Oil drain line with valve
- Mounting System
- Captive linear vibration isolators between base and engine-generator
- Includes lifting provisions and termination points for coolant
- Starting / Charging System
- 12 Volt battery with rack and cables
- General
- Engine and alternator pre-paint, Caterpillar yellow
C2.2 (50 Hz) Optional Equipment
- Alternator Options
- Coastal insulation protection
- Certificates
- Global certification for CIS
- European upgrade to STD set for CE certificate
- Circuit Breakers
- 4 Pole circuit breaker
- Pad-locable breaker device
- Control Panel Options
- EMCP 4.2
- Volt free contacts for common alarm
- Volt free contacts for genset running
- Battery charger
- Emergency stop with key
- Cooling System
- Coolant heater
- Enclosures
- Sound attenuated enclosure (GALV)
- Single point lift for enclosure
- Fuel System
- Skidbase for open sets
- Skidbase for Enclosures
- DEFRA bunded fuel tank
- Low fuel level alarm
- Fuel transfer control
- 1000 hr extended service interval
- Base feet
- Mounting Options
- Battery removal
- Industrial silencer removal
- Silencer installation kit
- Special Test and Inspection
- PGS test report @ 1.0 power factor
- General
- Radiator Stone Guard
- Packing Case - compact set
- Packing case - canopied set
360° INTERACTIVE
Exterior
Interior
RELATED PRODUCTS
3412C (50 Hz)
power generation diesel hfo
- Height Maximum: 1906 mm75 in
- Length Maximum: 162.4 mm4135 in
- Width Maximum: 1989 mm78.3 in
3512A (50 Hz)
power generation diesel hfo
- Minimum Rating: 1000 kVA
- Maximum Rating: 1400 kVA
- Voltage: 220 to 13800 Volts
3512B (50 Hz)
power generation diesel hfo
- Height Maximum: 2367 mm93.2 in
- Length Maximum: 5637 mm221.9 in
- Width Maximum: 2286 mm90 in
3516 (50 Hz)
power generation diesel hfo
- Height Maximum: 2367 mm93.2 in
- Length Maximum: 5919 mm232.9 in
- Width Maximum: 2286 mm90 in
3516B (50 Hz)
power generation diesel hfo
- Height Maximum: 2367 mm93.2 in
- Length Maximum: 5928 mm233.4 in
- Width Maximum: 2286 mm90 in
3516B DGB™ (50 Hz)
power generation diesel hfo
- Minimum Rating: 1750 kVA
- Maximum Rating: 2275 kVA
- Voltage: 220 to 11000
3516E (50 Hz)
power generation diesel hfo
- Height Maximum: 3476 mm136.9 in
- Length Maximum: 9195 mm362 in
- Width Maximum: 2552 mm100.5 in
C1.5 (50 Hz)
power generation diesel hfo
- Height Maximum: 1054 mm41.5 in
- Length Maximum: 1400 mm55.1 in
- Width Maximum: 620 mm24.4 in
C2.2 (50 Hz)
power generation diesel hfo
- Height Maximum: 1115 mm43.9 in
- Length Maximum: 1500 mm59.1 in
- Width Maximum: 620 mm24.4 in