C7.1 (50 Hz) power generation diesel hf

  • Height Maximum 1626 mm64 in
  • Length Maximum 2500 mm98.4 in
  • Width Maximum 1320 mm52 in

SPECIFICATIONS

  • Height Maximum 1626 mm64 in
  • Length Maximum 2500 mm98.4 in
  • Width Maximum 1320 mm52 in
  • Minimum Rating 135 kVA
  • Maximum Rating 218 kVA
  • Voltage 110 to 480 Volts
  • Frequency 50 Hz
  • Speed 1500 rpm
  • Emissions Fuel Strategy Non Regulated, EU Stage IIIA
  • Engine Model Cat® C7.1
  • Compression Ratio 16.0:1, 18.2:1
  • Aspiration Turbocharged, Air to Air Aftercooled
  • Governor Type Mechanical
  • Fuel System Direct Injection
  • Bore 105 mm4.1 in
  • Displacement 7 l427.8 in³
  • Stroke 135 mm5.3 in
  • Industry power-generation-diesel-hfo

EQUIPMENT

C7.1 (50 Hz) Standard Equipment

  • Air Inlet System
    • Air Cleaner; light duty with disposable element
  • Control Panels
    • EMCP 4.1
  • Cooling System
    • Radiator and cooling fan with guards
    • Coolant drain line with valves
    • Fan drive, battery charging alternator drive
    • Caterpillar extended life coolant
  • Fuel System
    • Standard open set fuel tank / base supplied
    • Base, formed steel with single wall integral 8-hour fuel tank
  • Generator and Generator Attachments
    • 12 leads
    • IP23 protection
    • Voltage regulator (single phase sensing)
    • Tower panel, IP22, bottom cable entry
    • Segregated low voltage (AC/DC) wiring panel
    • Circuit breaker, IEC, 3 pole, mounted in tower panel
  • Governing System
    • Mechanical and electrical governing system - model dependent
  • Lube System
    • Lubricating oil
    • Oil drain line with valve
  • Mounting System
    • Captive linear vibration isolators between base and engine-generator
    • Includes lifting provision and drag points
    • Termination points for coolant and lube oil drain lines
  • Starting / Charging System
    • 24V battery with rack and cables
  • General
    • Engine and alternator pre-paint, Caterpillar Yellow

C7.1 (50 Hz) Optional Equipment

  • Alternator System
    • R frame auxiliary winding: R2273L4 SE aux alt 07, aux alt 08 and aux alt 10
    • Optional LC frame alternators
    • Optional LC frame alternator with coastal insulation protection
    • Permanent magnet
    • 3 Phase sensing
    • Quatrature droop king
    • Anti-condensation heater
  • Circuit Breakers
    • 4 Pole 250A, 400A and 630 A Circuit Breakers
    • Padlockable breaker device
  • Control System
    • EMCP 4.2
  • Control Panel Options
    • Volt free contacts
    • Speed adjust contacts
    • Speed adjust potentiometer
    • Panel mounted audible alarm
    • Earth fault (2 wire only)
    • Earth leakage (2 wire only)
    • Overload shutdown via breaker
    • Battery charger
    • Emergency stop with key
    • Control panel heater
  • Cooling System
    • Coolant heater
    • Low coolant temperature
    • Low coolant level shutdown
  • Enclosures
    • Sound attenuated level 2 enclosure
    • Sound attenuated level 1 enclosure
    • Rental options (CAE only) - Single point lift
    • Rental options (CAE only) - Rental pack
    • Rental options (CAE only) - CEE form sockets for enclosure
    • Rental options (CAE only) - Socket blanking plate
  • European Certifications
    • Upgrade to STD set for CE
  • Fuel Systems
    • Open set narrow tankbase
    • Compact skidbase for open sets
    • Skidbase for CALG enclosure sets
    • DEFRA bunded fuel tank
    • Low fuel level shutdown
    • Low fuel level alarm
    • High fuel level alarm
  • Global Certifications
    • Certification for CIS
  • Mounting Options
    • Electronic governor
    • Residential silencer
    • Silencer installation kit
  • Test Reports
    • PGS test report @ 1.0 power factor
    • PGS test report @ 0.8 power factor
  • General
    • Stone guards / radiator trans flange

RELATED PRODUCTS

3412C (50 Hz) - Power-generation-diesel-hfo

3412C (50 Hz)

power generation diesel hfo

  • Height Maximum: 1906 mm75 in
  • Length Maximum: 162.4 mm4135 in
  • Width Maximum: 1989 mm78.3 in
Get a quote
3512A (50 Hz) - Power-generation-diesel-hfo

3512A (50 Hz)

power generation diesel hfo

  • Minimum Rating: 1000 kVA
  • Maximum Rating: 1400 kVA
  • Voltage: 220 to 13800 Volts
Get a quote
3512B (50 Hz) - Power-generation-diesel-hfo

3512B (50 Hz)

power generation diesel hfo

  • Height Maximum: 2367 mm93.2 in
  • Length Maximum: 5637 mm221.9 in
  • Width Maximum: 2286 mm90 in
Get a quote
3516 (50 Hz) - Power-generation-diesel-hfo

3516 (50 Hz)

power generation diesel hfo

  • Height Maximum: 2367 mm93.2 in
  • Length Maximum: 5919 mm232.9 in
  • Width Maximum: 2286 mm90 in
Get a quote
3516B (50 Hz) - Power-generation-diesel-hfo

3516B (50 Hz)

power generation diesel hfo

  • Height Maximum: 2367 mm93.2 in
  • Length Maximum: 5928 mm233.4 in
  • Width Maximum: 2286 mm90 in
Get a quote
3516B DGB™ (50 Hz) - Power-generation-diesel-hfo

3516B DGB™ (50 Hz)

power generation diesel hfo

  • Minimum Rating: 1750 kVA
  • Maximum Rating: 2275 kVA
  • Voltage: 220 to 11000
Get a quote
3516E (50 Hz) - Power-generation-diesel-hfo

3516E (50 Hz)

power generation diesel hfo

  • Height Maximum: 3476 mm136.9 in
  • Length Maximum: 9195 mm362 in
  • Width Maximum: 2552 mm100.5 in
Get a quote
C1.5 (50 Hz) - Power-generation-diesel-hfo

C1.5 (50 Hz)

power generation diesel hfo

  • Height Maximum: 1054 mm41.5 in
  • Length Maximum: 1400 mm55.1 in
  • Width Maximum: 620 mm24.4 in
Get a quote
C2.2 (50 Hz) - Power-generation-diesel-hfo

C2.2 (50 Hz)

power generation diesel hfo

  • Height Maximum: 1115 mm43.9 in
  • Length Maximum: 1500 mm59.1 in
  • Width Maximum: 620 mm24.4 in
Get a quote