PARTS.CAT.COM

Enquiry Basket Summary

Submit an enquiry now on your items in your basket and one of our sales team will be in touch

ENQUIRE NOW

3516B (50 Hz) power generation diesel hf

  • Height Maximum 2367 mm93.2 in
  • Length Maximum 5928 mm233.4 in
  • Width Maximum 2286 mm90 in

SPECIFICATIONS

  • Height Maximum 2367 mm93.2 in
  • Length Maximum 5928 mm233.4 in
  • Width Maximum 2286 mm90 in
  • Minimum Rating 1750 kVA
  • Maximum Rating 2500 kVA
  • Voltage 220 to 13800
  • Frequency 50 Hz
  • Speed 1500 rpm
  • Emissions Fuel Strategy Low Fuel Consumption, Low Emissions
  • Engine Model 3516B TA, V-16, 4-Stroke Water-Cooled Diesel
  • Compression Ratio 14.0:1 Std 15.5:1 HD
  • Aspiration TA
  • Governor Type Adem™3
  • Fuel System Electronic unit injection
  • Bore 170 mm6.69 in
  • Displacement Hd 78.08 l4764.73 in³
  • Displacement Std 69 l4210.64 in³
  • Stroke Hd 215 mm8.46 in
  • Stroke Standard 190 mm7.48 in
  • Industry power-generation-diesel-hfo

EQUIPMENT

3516B (50 Hz) Standard Equipment

  • Air Inlet System
    • Air Cleaner; single element canister type
  • Control Panels
    • EMCP 4.2B
    • Emergency stop pushbutton
    • 24 Volt DC operation
    • Environmental sealed front face
    • Text alarm/event descriptions
    • Generator mounted - rear facing
    • Generator set packages include Caterpillar' s Voltage Regulator
    • IVR includes:
    • Reactive droop capability
    • 3-phase voltage sensing
    • KVAR/PF modes
    • RFI suppression
    • Min / max exciter
    • Limiter and exciter diode monitor
    • Controls:
    • Speed adjust
    • Auto/start/stop control
    • Engine cool-down timer
    • Engine cycle crank
    • Alarm acknowledge
    • Lamp test
    • Load histogram feature
    • PLC functionality
    • Customizable screens
    • 0 True RMS AC metering, 3-phase, +/-2% accuracy
    • Digital indication for:
    • RPM - DC volts
    • DC volts
    • Operating hours
    • Oil pressure (psi, kPa or bar)
    • Coolant temperature
    • Volts (L-L & L-N)
    • Frequency (Hz)
    • Amps (per phase & average)
    • Power Factor (per phase & average)
    • kW (per phase, average & percent)
    • kVA (per phase, average & percent)
    • kW-hr (total) - kVAr-hr (total)
    • Warning / shutdown with common LED indication of shutdowns for:
    • Low oil pressure
    • High coolant temperature
    • Overspeed - Emergency stop
    • Emergency stop - Failure to start (overcrank)
    • Failure to start (overcrank)
    • Low coolant temperature
    • Low coolant level
    • Programmable protective relaying functions:
    • Over / under voltage (2 7/ 59)
    • Over / under frequency (81 o/u)
    • Reverse power (kW) (32)
    • Reverse reactive power (kVAr) (32RV)
    • Overcurrent (50 / 51)
    • Communications:
    • Customer data link (Modbus RTU)
    • Accessory module data link
    • Serial annunciator module data link
    • Cat Connect
    • 3 Analog inputs
    • 6 Customer programmable digital inputs
    • Number of I/O varies on options selected:
    • 4 Programmable relay outputs (Form A)
    • 4 Programmable relay outputs (Form A)
    • 1 Programmable relay outputs (Form C
    • 1 Programmable digital outputs
  • Cooling System
    • Certified standard PGS provided
    • ATAAC - 3516E Package Radiators shipped installed
  • Exhaust System
    • Dry exhaust manifold
    • Flanged faced outlet(s)
  • Fuel System
    • Secondary fuel filters
    • Fuel cooler; not included with packages without radiator
    • Flexible fuel lines - shipped loose
    • Fuel priming pump
  • General
    • Caterpillar yellow with high gloss black rails and radiator
    • Right hand servicing
    • Flywheel and flywheel housing - SAE No. 00
    • SAE Standard rotation
  • Generator and Attachments
    • 3 Phase brushless, salient pole
    • 6 Leads
    • Low Voltage:
    • Random wound
    • Internal excitation
    • Winding temperature detectors
    • NEMA Class H insulation
    • Class H temperature rise at 40C ambient (125C prime / 150C standby)
    • Busbar connections, top center mounted, top cable entry
    • NEMA standard hole pattern
    • Medium Voltage:
    • Form wound
    • Permanent magnet
    • Winding temperature detectors
    • NEMA Class H insulation, Class H temperature rise at 40C ambient (125C prime / 150C standby
    • Busbar connections, right side extension box, bottom cable entry
    • NEMA standard hole pattern
    • High Voltage:
    • Form wound - Permanent magnet
    • Permanent magnet
    • Winding temperature detectors
    • Anti Condensation Space Heater
    • Class H insulation, Class F temperature rise at 40C ambient (105C prime / 130C standby)
  • Governing System
    • ADEM A3
  • Literature
    • English
  • Lubrication System
    • Lubricating oil
    • Gear type lube oil pump
    • Integral lube oil cool
    • Oil filter, filler and dipstick
    • Oil drain lines and valve
    • Fumes disposal
  • Mounting System
    • Rails - engine / generator / radiator mounting
    • Anti-vibration mounts (shipped loose)
    • Rubber anti-vibration mounts (shipped loose)
  • Starting System
    • 24 Volt electric starting motor
    • 45 Amp charging alternator
    • Battery and battery rack w/cables
    • Battery disconnect switch

3516B (50 Hz) Optional Equipment

  • Control System
    • EMCP 4.3, EMCP 4.4
  • Air Inlet System
    • Single element filter
    • Dual element air cleaner
  • Cooling System
    • Standard ambient radiators
    • Standard ambient ATAAC radiators
    • Optional installed radiators
    • Optional installed ATAAC radiators
    • Water level switch gauges
    • Coolant
  • Crankcase System
    • No explosion relief valves
    • Explosion relief valves
    • Ventilation system
  • Exhaust System
    • Elbows
    • Flange and exhaust expanders
    • Flanges
    • Flexible fittings
    • Y-Adapters
    • Mufflers
    • Exhaust offset
    • Tier 4 clean emissions module
    • Tier 4 dosing cabinet
    • Tier 4 clean emission MOD Kits
    • Clean emission parts
  • Fuel System
    • Primary Fuel Filter
    • Fuel Priming Pumps (Tier 4) - Manual or electric
  • General
    • US aid emblem
    • Special paint (Colors other than Caterpillar yellow or high performance paints)
  • Generators and Attachments
    • Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame
    • Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, PM, No. of Leads = 6, Pitch = .6667: 1600 and 1800 Frames
    • Space heater
    • Generator conversion
    • Thermostate for space heater
    • Alternator air cleaner
    • Differential current transformers (DCT)
    • Differntial current transformers (DCT) 8.7 kV and 15 kV classes
  • Instrumentation
    • Pyrometer and thermocouples
  • Lubrication System
    • Lube oil in standard sump
    • Oil level regulator
    • Prelube pumps
  • Mounting System
    • Puck style low efficiency isolators
    • Spring type vibration isolators
    • IBC vibration isolators
  • Power Connections
    • Ground cables between generator and terminal box
    • Neutral ground connections
    • Center post busbar
    • Right side power connections
    • Left side power connections
    • Rear power connections
    • 2700 Frame, four lead, four terminal
    • Low voltage circuit breakers
  • Special Tests / Reports
    • Canadian Standards Association certification
    • IBC certification
    • OSHPD certification
    • PGS test report @ 1.0 power factor
    • PGS test report @ 0.8 power factor
    • Standard engine test charge
    • generator test report
    • Fuel consumption test
    • Generator set fuel consumption test
    • Torsional vibration analysis reports
  • Starting and Charging
    • Engine barring device
    • 24 Volt battery set - Dry
    • 10, 20, 35 and 50 amp battery chargers
    • Electric starting motors
    • Air starting motors
    • Starter cover
    • Air pressure regulator
    • Jacket water heaters
  • Extended Service Coverage
    • Platinum, Gold and Silver coverage

360° INTERACTIVE

Exterior

Interior

RELATED PRODUCTS

3412C (50 Hz) - Power-generation-diesel-hfo

3412C (50 Hz)

power generation diesel hfo

  • Height Maximum: 1906 mm75 in
  • Length Maximum: 162.4 mm4135 in
  • Width Maximum: 1989 mm78.3 in
Get a quote
3512A (50 Hz) - Power-generation-diesel-hfo

3512A (50 Hz)

power generation diesel hfo

  • Minimum Rating: 1000 kVA
  • Maximum Rating: 1400 kVA
  • Voltage: 220 to 13800 Volts
Get a quote
3512B (50 Hz) - Power-generation-diesel-hfo

3512B (50 Hz)

power generation diesel hfo

  • Height Maximum: 2367 mm93.2 in
  • Length Maximum: 5637 mm221.9 in
  • Width Maximum: 2286 mm90 in
Get a quote
3516 (50 Hz) - Power-generation-diesel-hfo

3516 (50 Hz)

power generation diesel hfo

  • Height Maximum: 2367 mm93.2 in
  • Length Maximum: 5919 mm232.9 in
  • Width Maximum: 2286 mm90 in
Get a quote
3516B (50 Hz) - Power-generation-diesel-hfo

3516B (50 Hz)

power generation diesel hfo

  • Height Maximum: 2367 mm93.2 in
  • Length Maximum: 5928 mm233.4 in
  • Width Maximum: 2286 mm90 in
Get a quote
3516B DGB™ (50 Hz) - Power-generation-diesel-hfo

3516B DGB™ (50 Hz)

power generation diesel hfo

  • Minimum Rating: 1750 kVA
  • Maximum Rating: 2275 kVA
  • Voltage: 220 to 11000
Get a quote
3516E (50 Hz) - Power-generation-diesel-hfo

3516E (50 Hz)

power generation diesel hfo

  • Height Maximum: 3476 mm136.9 in
  • Length Maximum: 9195 mm362 in
  • Width Maximum: 2552 mm100.5 in
Get a quote
C1.5 (50 Hz) - Power-generation-diesel-hfo

C1.5 (50 Hz)

power generation diesel hfo

  • Height Maximum: 1054 mm41.5 in
  • Length Maximum: 1400 mm55.1 in
  • Width Maximum: 620 mm24.4 in
Get a quote
C2.2 (50 Hz) - Power-generation-diesel-hfo

C2.2 (50 Hz)

power generation diesel hfo

  • Height Maximum: 1115 mm43.9 in
  • Length Maximum: 1500 mm59.1 in
  • Width Maximum: 620 mm24.4 in
Get a quote