C32 Tier 3 / IMO II marine power system

  • Minimum Rating 219 ekW
  • Maximum Rating 940 ekW
  • Frequency 60hz

SPECIFICATIONS

  • Minimum Rating 219 ekW
  • Maximum Rating 940 ekW
  • Frequency 60hz
  • Aspiration Turbocharged-aftercooled aspiration
  • Bore 145 mm5.71 in
  • Displacement 32.1 l1959 in³
  • Stroke 162 mm6.38 in
  • Configuration Vee-12, 4-stroke-Cycle-Diesel
  • Length 167.2 in/4245 mm (minimum), 226.1 in/5742 mm (maximum)
  • Width 59.9 in/1521 mm (minimum), 89.8 in/2280 mm (maximum)
  • Height 70.4 in/1747 mm (minimum), 92.8 in/2356 mm (maximum)
  • Emissions U.S. EPA Tier 3 / IMO II emissions certified
  • Oil Change Interval 750 hrs
  • Governor Electronic (A4 ECM)
  • Generator SR5 - Form Wound
  • Cooling Heat exchanger, keel or radiator cooled
  • Rated Engine Speed 1800 rpm
  • Refill Capacity Lube Oil System w/ oil filter change: 146 L (38.5 gal)
  • Industry marine-power-systems

EQUIPMENT

C32 Tier 3 / IMO II Standard Equipment

  • AIR INLET SYSTEM
    • Separate circuit aftercooled (SCAC)
  • CONTROL SYSTEM
    • 24V control system
  • COOLING SYSTEM
    • Heat exchanger, keel or radiator cooled
    • Watercooled exhaust manifold and turbocharger
    • Hard seawater lines – no flexible hoses
    • Flanges for cooling connections, ANSI or DIN
  • FUEL SYSTEM
    • Duplex fuel filters with hybrid fuel lines
    • Fuel transfer and priming pump
  • GENERATORS AND GENERATOR ATTACHMENTS
    • IP23, air cooled, form wound SR5 generator offered in 440, 480 and 690V
  • LUBE SYSTEM
    • Oil fill, simplex filter and dipstick
  • MOUNTING SYSTEM
    • Helical spring/rubber isolated mounting for vibration and structure borne noise reduction
  • GENERAL
    • Right or left hand service sides
    • Customer wiring and service tool connector

C32 Tier 3 / IMO II Optional Equipment

  • AIR INLET SYSTEM
    • Closed crankcase ventilation
  • ALARM AND PROTECTION
    • MGCP II or MGCP IIIB control panel with Cat® alarm and protection system
    • IP44 generator protection
  • EXHAUST SYSTEM
    • Muffler
    • SOLAS approved spray shielding
  • CHARGING SYSTEM
    • Charging alternator
  • CONTROL SYSTEM
    • EMCP 4.2 control panel
  • FUEL SYSTEM
    • Installed primary fuel filter with water separator and manual or electric priming pump
    • Fuel cooler
  • LUBE SYSTEM
    • Duplex oil filters
  • STARTING SYSTEM
    • Starting motors – air, electric or dual

RELATED PRODUCTS

3512E - Marine-power-systems

3512E

marine power systems

  • Aspiration: TA
  • Bore: 170 mm6.69 in
  • Displacement: 58.6 l3574 in³
Get a quote
3516E - Marine-power-systems

3516E

marine power systems

  • Aspiration: TA
  • Bore: 170 mm6.69 in
  • Displacement: 78 l4765 in³
Get a quote
C18 IMO II - Marine-power-systems

C18 IMO II

marine power systems

  • Minimum Rating: 301 bkW404 BHP
  • Maximum Rating: 492 bkW660 BHP
  • Aspiration: TA, TTA
Get a quote
C18 Tier 3 - Marine-power-systems

C18 Tier 3

marine power systems

  • Minimum Rating: 465 bkW624 BHP
  • Maximum Rating: 599 bkW803 BHP
  • Aspiration: TA, TTA
Get a quote
C280 - Marine-power-systems

C280

marine power systems

  • Minimum Rating: 1730 bkW2320 BHP
  • Maximum Rating: 5420 bkW7268 BHP
  • Aspiration: TA
Get a quote
C32 IMO II - Marine-power-systems

C32 IMO II

marine power systems

  • Minimum Rating: 590 bkW791 BHP
  • Maximum Rating: 994 bkW1333 BHP
  • Aspiration: TTA
Get a quote
C32 IMO III - Marine-power-systems

C32 IMO III

marine power systems

  • Minimum Rating: 262 bkW352 BHP
  • Maximum Rating: 874 bkW1172 BHP
  • Aspiration: Turbocharged-aftercooled aspiration
Get a quote
C32 Tier 3 - Marine-power-systems

C32 Tier 3

marine power systems

  • Minimum Rating: 781 bkW1047 BHP
  • Maximum Rating: 994 bkW1333 BHP
  • Aspiration: TTA
Get a quote
C32 Tier 3 / IMO II - Marine-power-systems

C32 Tier 3 / IMO II

marine power systems

  • Minimum Rating: 234 bkW314 BHP
  • Maximum Rating: 994 bkW1333 BHP
  • Aspiration: Turbocharged-aftercooled aspiration
Get a quote