OVERVIEW
Cat® C2.2 Diesel Marine Generator Set has single phase ratings of 50 Hertz at 16.0 and 22.5 ekW and 60 Hertz at 19.0 and 27.0 ekW that meet U.S. EPA Tier 3 and EU IW emission standards.The Cat® C2.2 also has three phase ratings of 50 Hertz at 16.0 and 22.5 ekW and 60 Hertz at 19.5 and 27.0 ekW that meet U.S. EPA Tier 3 and EU IW emissions standards. This marine gen set is available in 12 or 24 volt as an open gen set or as an enclosed package.
SPECIFICATIONS
- Minimum Rating 16 ekW (16kVA)
- Maximum Rating 27 ekW (27 kVA)
- Frequency 50 Hz or 60 Hz
- Speed 1500 rpm (50Hz) or 1800 rpm (60 Hz
- Emissions Fuel Strategy EPA Tier 3, IMO NST, EU IW
- Engine Model C2.2, In-line 4, 4-Stroke-Cycle Diesel
- Aspiration Naturally Aspirated
- Governor Type Electrical Ischronous
- Fuel System Fuel filter — RH or LH service, fuel priming, fuel transfer pump, flexible fuel lines
- Bore 84 mm3.31 in
- Displacement 2.2 l135 in³
- Stroke 100 mm3.94 in
- Number Of Poles 4
- Insulation Class H
- Excitation AREP
- Voltage Regulation ±0.5%
- Frame Size 2.2
- Ip Rating 23
- Voltage Regulator Steady State
- Pitch 2/3 pitch
- Number Of Leads 4
- Wave Form Deviation Line To Line <2%
- Height Enclosed Set 775 mm31 in
- Height Open Set 825 mm32 in
- Length Enclosed Set 1170 mm46 in
- Length Open Set 1147 mm45 in
- Maximum Approximate Weight 466 kg1027 lb
- Minimum Approximate Weight 389 kg857 lb
- Width Enclosed Set 608 mm24 in
- Width Open Set 521 mm20.5 in
- Industry marine-power-systems
- Overview Cat® C2.2 Diesel Marine Generator Set has single phase ratings of 50 Hertz at 16.0 and 22.5 ekW and 60 Hertz at 19.0 and 27.0 ekW that meet U.S. EPA Tier 3 and EU IW emission standards.The Cat® C2.2 also has three phase ratings of 50 Hertz at 16.0 and 22.5 ekW and 60 Hertz at 19.5 and 27.0 ekW that meet U.S. EPA Tier 3 and EU IW emissions standards. This marine gen set is available in 12 or 24 volt as an open gen set or as an enclosed package.
EQUIPMENT
C2.2 Standard Equipment
- Air Inlet System
- Air cleaner, single element canister type with rain cap (open generator set only)
- Cooling System
- Belt-driven centrifugal jacket water pump, gear-driven seawater pump, heat exchanger with copper nickel tubes, expansion tank
- Control System
- Electronic isochronous governor
- Exhaust System
- Watercooled exhaust manifold and elbow
- Fuel System
- Fuel filter — RH or LH service, fuel priming, fuel transfer pump, flexible fuel lines
- Generator
- Single-phase — brushless, shunt excited, 4-pole, 4-lead reconnectable with class H insulation, automatic voltage regulation ±0.5%, 2/3 pitch, IP23 water protection, solid state voltage regulator with integral voltage adjustment potentiometer, connection poles;
- Lube System
- Lubricating oil, oil filter (RH), dipstick (RH), fumes disposal (closed system)
- Mounting System
- Anti-vibration mounts, connected to drip tray and steel base sitting on PVC foam sound-absorbent pad
- Protection System
- Electronic automatic safety shutdown for low oil pressure, high water temperature, high exhaust (wet exhaust only) temperature, and overspeed
- Starting System
- 12 or 24 volt electronic starting motor, 12 volt 55 amp alternator
- General
- Single-side service (RH), decals, literature
RELATED PRODUCTS
![3512E - Marine-power-systems](https://barloworld-equipment.com/hubfs/products/marine-power-systems-C2.2-2c54b383aa00c88ac4d1cf092bcb1210.jpeg)
3512E
marine power systems
- Aspiration: TA
- Bore: 170 mm6.69 in
- Displacement: 58.6 l3574 in³
![C18 IMO II - Marine-power-systems](https://barloworld-equipment.com/hubfs/products/marine-power-systems-C2.2-2c54b383aa00c88ac4d1cf092bcb1210.jpeg)
C18 IMO II
marine power systems
- Minimum Rating: 301 bkW404 BHP
- Maximum Rating: 492 bkW660 BHP
- Aspiration: TA, TTA
![C18 Tier 3 - Marine-power-systems](https://barloworld-equipment.com/hubfs/products/marine-power-systems-C2.2-2c54b383aa00c88ac4d1cf092bcb1210.jpeg)
C18 Tier 3
marine power systems
- Minimum Rating: 465 bkW624 BHP
- Maximum Rating: 599 bkW803 BHP
- Aspiration: TA, TTA
![C280 - Marine-power-systems](https://barloworld-equipment.com/hubfs/products/marine-power-systems-C2.2-2c54b383aa00c88ac4d1cf092bcb1210.jpeg)
C280
marine power systems
- Minimum Rating: 1730 bkW2320 BHP
- Maximum Rating: 5420 bkW7268 BHP
- Aspiration: TA
![C32 IMO II - Marine-power-systems](https://barloworld-equipment.com/hubfs/products/marine-power-systems-C2.2-2c54b383aa00c88ac4d1cf092bcb1210.jpeg)
C32 IMO II
marine power systems
- Minimum Rating: 590 bkW791 BHP
- Maximum Rating: 994 bkW1333 BHP
- Aspiration: TTA
![C32 IMO III - Marine-power-systems](https://barloworld-equipment.com/hubfs/products/marine-power-systems-C2.2-2c54b383aa00c88ac4d1cf092bcb1210.jpeg)
C32 IMO III
marine power systems
- Minimum Rating: 262 bkW352 BHP
- Maximum Rating: 874 bkW1172 BHP
- Aspiration: Turbocharged-aftercooled aspiration
![C32 Tier 3 - Marine-power-systems](https://barloworld-equipment.com/hubfs/products/marine-power-systems-C2.2-2c54b383aa00c88ac4d1cf092bcb1210.jpeg)
C32 Tier 3
marine power systems
- Minimum Rating: 781 bkW1047 BHP
- Maximum Rating: 994 bkW1333 BHP
- Aspiration: TTA
![C32 Tier 3 / IMO II - Marine-power-systems](https://barloworld-equipment.com/hubfs/products/marine-power-systems-C2.2-2c54b383aa00c88ac4d1cf092bcb1210.jpeg)
C32 Tier 3 / IMO II
marine power systems
- Minimum Rating: 234 bkW314 BHP
- Maximum Rating: 994 bkW1333 BHP
- Aspiration: Turbocharged-aftercooled aspiration