SPECIFICATIONS
- Minimum Rating 2880 ekW3600 kV·A
- Maximum Rating 2880 ekW3600 kV·A
- Aspiration Turbocharged-Aftercooled
- Bore 255 mm10 in
- Displacement 184 l11204 in³
- Stroke 400 mm15.7 in
- Length 9516 mm374.6 in
- Width 2534 mm99.8 in
- Height 4437 mm174.7 in
- Emissions IMO Tier II
- Weight 56000 kg123459 lb
- Generator Set Control Electronic
- Engine Control Electronic
- Industry oil-and-gas
EQUIPMENT
9CM25C Standard Equipment
- Engine
- Motor-driven barring gear, fitted on engine
- Reversing contractor and pushbutton switch with cable
- Electronic speed setting equipment with actuator and speed pick-up
- Emergency shutdown equipment with pushbutton, separate, for manual emergency stop
- Engine Indicators
- Gauge board with set liquid damped pressure gauges for: fuel, lubricating oil, fresh water, starting air, and charge air.
- On-engine thermometers for fuel, lubricating oil, fresh water, and charge air
- Electric remote speed indicator
- Turbocharger and remote speed indicator
- Exhaust gas temperature indicator
- Control
- Manual control on engine, including: control panel with start /stop key, speed setting device, mechanical shutdown device, change over of control functions from engine to remote control
- Starting solenoid valve on engine, 24 V DC
- Separate electronic speed governor
- Monitoring for Unattended Operation
- Pressure switches, mounted on engine, for: - Lube oil pressure at full load below danger level - Low lube oil pressure - Lube oil pressure below danger level - Lube oil pressure prelubrication failed - Low fresh water pressure at engine inlet - Fresh water pressure at engine inlet below danger level - Low fresh water pressure in LT circuit - Low starting air pressure - Low control air pressure engine/shutdown air pressure - Low fuel pressure at engine inlet Switches for: - High lube oil temperature at engine inlet - Lube oil temperature at engine inlet above danger level - High water temperature at engine inlet - Water temperature at engine outlet above danger level - High charge-air temperature at engine inlet - Detection of water in charge-air duct - Leak fuel level - Alarm contact for high differential pressure at fuel filter - Alarm contact for high differential pressure at lube oil back flushing filter - Set of thermocouples after each cylinder, before and after turbocharger - Crankcase oil mist detector Control Cabinet with housings for wall mounting, including: - Protection equipment designed for automatic and manual stop input signals, starting interlock input signals, monitoring for the wire break of the input signal units and the emergency shutdown solenoid - Speed recording system for overspeed, firing speed and minimum speed - Start /stop logic, controlled by engine automatic start (optional) - Service hour counter - Noris alarm system, cassette type, designed for alarm inputs for the engine including exhaust mean-value monitoring equipment as well as alarm inputs for the propulsion plant - Group alarm panel for the bridge and with optional and acoustical alarm equipment
- Starting Air System
- Separate non-return valve for the starting air pipe to the engine
- Air Intake System
- Air intake filter, fitted on the turbocharger
- Air bottles, separate
- Diesel Oil System
- Separate circulating pump driven by electric motor, horizontal or vertical
- Duplex filter with differential pressure indication
- Exhaust System
- Turbocharger at free end with transition nozzle (0 degrees from the vertical and away from engine), with compressor cleaning device
- Expansion joint separate
- Separate silencer and spark arrester, unlagged 35 dB(A)
- Fresh Cooling Water System
- HT pump, fitted on engine
- LT pump, separate, vertical design, electric motor driven
- HT thermostat, not powered and separate
- Engine preheating equipment, fitted on base frame
- Lubricating Oil System
- Plate cooler, fitted on engine
- Force pump, fitted on engine
- Prelubrication pump, fitted on base frame, electric motor driven
- Boll and Kirch automatic backflushing filter, separate
- Duplex filter with differential pressure indication, separate
- Pressure control valve, separate
- Thermostat, not powered, separate
- Connecting Parts - Engine
- Set of connecting parts between flange coupling and flywheel
- Flexible flange coupling between engine and generator
- Base frame with flywheel guard and incorporating lube oil sump tank, for engine and generator
- Mounting of engine and generator on the base frame
- Set of bonded rubber rails for resilient mounting of the base frame
- Set of flexible pipe connections
- Tools
- Set of tools for turbocharger
- Set of tools for turbocharger
- Inside micrometer for cylinder liners
- Ruler for cylinder liner
- Spare Parts
- Set of engine spare parts for unrestricted operation
- Set of spare flexible pipe connections
RELATED PRODUCTS
CN1566 Electric Motor
oil and gas
- Electric Motor Type: Squirrel Cage Induction Motor
- Full Load Speed: 1189 r/min1189 r/min
- Mounting Designation: F1 or F2
CN3086 Electric Motor for Gas Compression
oil and gas
- Electric Motor Type: Squirrel Cage Induction Motor
- Full Load Speed: 892 r/min892 r/min
- Mounting Designation: F1 or F2
CN3586 Electric Motor for Gas Compression
oil and gas
- Electric Motor Type: Squirrel Cage Induction Motor
- Full Load Speed: 894 rpm
- Mounting Designation: F1 or F2
CN5086 Electric Motor
oil and gas
- Electric Motor Type: Squirrel Cage Induction Motor
- Full Load Speed: 894 r/min894 r/min
- Mounting Designation: F1 or F2
3406C
oil and gas
- Minimum Rating: 217 bkW292 BHP
- Maximum Rating: 359 bkW482 BHP
- Aspiration: Turbocharged Aftercooled
3412
oil and gas
- Minimum Rating: 476 bkW638 BHP
- Maximum Rating: 551 bkW739 BHP
- Aspiration: Turbocharged Aftercooled
3508
oil and gas
- Minimum Rating: 709 bkW950 BHP
- Maximum Rating: 795 bkW1065 BHP
- Aspiration: Turbocharged Aftercooled
3512
oil and gas
- Minimum Rating: 1066 bkW1430 BHP
- Maximum Rating: 1195 bkW1600 BHP
- Aspiration: Turbocharged Aftercooled
3516
oil and gas
- Minimum Rating: 1417 bkW1900 BHP
- Maximum Rating: 1480 bkW1985 BHP