3512C Tier 3 marine power system

  • Aspiration TTA
  • Bore 170 mm6.69 in
  • Displacement 58.6 l3574 in³

SPECIFICATIONS

  • Aspiration TTA
  • Bore 170 mm6.69 in
  • Displacement 58.6 l3574 in³
  • Stroke 215 mm8.46 in
  • Configuration Vee 12, 4-Stroke-Cycle Diesel
  • Emissions EPA Tier 3, IMO II
  • Rotation From Flywheel End Counterclockwise or Clockwise
  • Power Range 1340-2366 bhp (1000-1765 bkW)
  • Maximum Height 2222.6 mm87.5 in
  • Maximum Length 2465 mm104.2 in
  • Maximum Width 2037 mm80.2 in
  • Minimum Dry Weight 7488 kg16508 lb
  • Minimum Height 2222.6 mm87.5 in
  • Minimum Length 2465 mm104.2 in
  • Minimum Width 2037 mm80.2 in
  • Speed Range 1600-1800 rpm
  • Industry marine-power-systems

EQUIPMENT

3512C Tier 3 Standard Equipment

  • Air Inlet System
    • Separate circuit aftercooler core, corrosion resistant coated (air side)
    • Powercore air cleaner
  • Control System
    • Dual Caterpillar A4 Electronic Engine Control with Electronic Unit Injector Fuel System
    • Rigid Wiring Harness (10 amp DC power required to drive Electronic Engine Control Module)
  • Exhaust System
    • 3500C engines:
  • Fuel System
    • Fuel transfer pump
    • Electronically Controlled Unit Injectors
  • Lube System
    • Crankcase breather groups, Top mounted
    • Oil filler and dipstick, LH or RH
    • Oil pump, gear type
    • 250 or 1000 hour sump oil pan
  • Mounting System
    • 3500C engines:
  • Power Takeoffs
    • Accessory drives: Lower RH, lower LH
    • Front housing, two-sided
  • Protection System
    • A4 Electronic Monitoring System provides customer programmable engine derating strategies to protect against adverse operating conditions
    • Emergency stop push button (located in Electronic Instrument Panel)
    • Safety shutoff protection:
  • General
    • Vibration damper and guard
    • Lifting eyes
    • NOTE: Engines for heat exchanger cooling do NOT include heat exchange
  • Flywheel and Flywheel Housing
    • Flywheel, SAE No. 00, 183 teeth
    • Flywheel housing, SAE No. 00
  • Cooling System
    • Oil cooler
    • Thermostats and housing, Full open temperature 92 C (198 F)
    • Jacket water pump, gear driven, centrifugal
    • Auxiliary fresh water pump
    • Aftercooler system: If using glycol, up to maximum 20% glycol concentration is allowed
  • Instrumentation
    • Electronic service meter, instrument panel (24V), start/stop switch, emergency stop button, maintenance due light, diagnostic light, warning light, maintenance clear switch, start motor magnetic switch, 15 and 3A breakers
    • Graphical Unit (Color Marine Power Display) for analog or digital of:

3512C Tier 3 Optional Equipment

  • Air Inlet System
    • Air Inlet Adapters
  • Charging System
    • Battery Chargers
    • Charging Alternator
  • Control System
    • Throttle Control
  • Cooling System
    • Coolant Shunt Tank
    • Cooling System Options
  • Exhaust System
    • Flexible Fittings
    • Elbows
    • Flanges
    • Flange and Exhaust Expanders
    • Mufflers
  • Fuel System
    • Fuel Cooler Heat Exchanger - Sea Water
    • Primary Fuel Filter
    • Fuel Level Switch
    • Rigid Fuel Lines
    • Flexible Fuel Lines
  • Instrumentation
    • Communication Modules
    • Color Marine Power Display System
    • Pilot House Instrument Panels
    • Marine Gear Sensors
  • Lube System
    • Sump Pumps
    • Lubricating Oil
  • Power Take-Offs
    • Stub Shafts
    • Crankshaft Pulleys
    • Damper Guard
    • Flexible Coupling and Guards
  • Marine Society Requirements
    • Green Passport Documentation
    • Spray Shielding
  • Protection System
    • Shutoff and Alarm Contactors
  • Special Appearance Packages
    • Special Appearance Packages with Chrome Covers
    • Yacht Class Finish
  • Starting System
    • Air Starting Motor Options
    • Battery Sets - 24 Volt - Dry
    • Battery Rack
  • Mounting System
    • Engine Supports
    • Vibration Isolation Mountings
  • Paints
    • Paint Color Options
  • Packing
    • Shrink Wrap Protection
    • Storage Preservation with Glycol Solution/Vapor Corrosion Inhibitor
    • Export Boxing
    • Export Packaging

RELATED PRODUCTS

3512E - Marine-power-systems

3512E

marine power systems

  • Aspiration: TA
  • Bore: 170 mm6.69 in
  • Displacement: 58.6 l3574 in³
Get a quote
3516E - Marine-power-systems

3516E

marine power systems

  • Aspiration: TA
  • Bore: 170 mm6.69 in
  • Displacement: 78 l4765 in³
Get a quote
C18 IMO II - Marine-power-systems

C18 IMO II

marine power systems

  • Minimum Rating: 301 bkW404 BHP
  • Maximum Rating: 492 bkW660 BHP
  • Aspiration: TA, TTA
Get a quote
C18 Tier 3 - Marine-power-systems

C18 Tier 3

marine power systems

  • Minimum Rating: 465 bkW624 BHP
  • Maximum Rating: 599 bkW803 BHP
  • Aspiration: TA, TTA
Get a quote
C280 - Marine-power-systems

C280

marine power systems

  • Minimum Rating: 1730 bkW2320 BHP
  • Maximum Rating: 5420 bkW7268 BHP
  • Aspiration: TA
Get a quote
C32 IMO II - Marine-power-systems

C32 IMO II

marine power systems

  • Minimum Rating: 590 bkW791 BHP
  • Maximum Rating: 994 bkW1333 BHP
  • Aspiration: TTA
Get a quote
C32 IMO III - Marine-power-systems

C32 IMO III

marine power systems

  • Minimum Rating: 262 bkW352 BHP
  • Maximum Rating: 874 bkW1172 BHP
  • Aspiration: Turbocharged-aftercooled aspiration
Get a quote
C32 Tier 3 - Marine-power-systems

C32 Tier 3

marine power systems

  • Minimum Rating: 781 bkW1047 BHP
  • Maximum Rating: 994 bkW1333 BHP
  • Aspiration: TTA
Get a quote
C32 Tier 3 / IMO II - Marine-power-systems

C32 Tier 3 / IMO II

marine power systems

  • Minimum Rating: 234 bkW314 BHP
  • Maximum Rating: 994 bkW1333 BHP
  • Aspiration: Turbocharged-aftercooled aspiration
Get a quote