SPECIFICATIONS
- Height Maximum 1361 mm53.6 in
- Length Maximum 1925 mm75.8 in
- Width Maximum 1120 mm44.1 in
- Minimum Rating 50 kVA
- Maximum Rating 110 kVA
- Voltage 110 to 480 Volts
- Frequency 50 Hz
- Speed 1500 rpm
- Emissions Fuel Strategy Non Regulated, EU Stage II and EU Stage IIIA
- Engine Model Cat® C4.4
- Compression Ratio 16.2:1, 17.25:1, 18.2:1 or 18.3:1
- Governor Type Mechanical
- Fuel System Direct Injection or Common Rail
- Bore 105 mm4.1 in
- Displacement 4.4 l268.5 in³
- Stroke 127 mm5 in
- Industry power-generation-diesel-hfo
EQUIPMENT
C4.4 (50 Hz) Standard Equipment
- Air Inlet System
- Air cleaner; light duty with disposable element
- Cooling System
- Radiator and cooling fan with guards
- Coolant drain line with valve
- Fan drive, battery charging alternator drive
- Caterpillar extended life coolant
- Exhaust System
- Stub pipe, gaskets, raincap and SAE exhaust flange for customer use - shipped loose
- Fuel System
- Standard open set fuel tank / base supplied base, formed steel with single wall integral 8-hour fuel tank
- Generators and Attachments
- 12 leads
- IP23 protection
- Voltage regulator (single phase sensing)
- Tower panel, IP22, bottom cable entry
- Segregated low voltage (AC/DC) wiring panel
- Circuit breaker, IEC, 3 pole, mounted in tower panel
- Governing System
- Mechanical and electrical governing system - model dependent
- Lube System
- Lubricating oil
- Oil drain line with valve
- Mounting System
- Captive linear vibration isolators between base and engine-generator
- Includes lifting provision and drag points
- Termination points for coolant and lube oil drain lines
- Starting/Charging System
- 24V battery with rack and cables
- General
- Engine and alternator pre-paint, Caterpillar Yellow
C4.4 (50 Hz) Optional Equipment
- Alternator System
- R frame auxilliary winding
- LC frame alternator
- LC frame alternator with coastal insulation protection
- Permanent magnet
- 3 phase sensing
- Quadrature droop kit
- Anti-condensation heater
- Circuit Breakers
- Circuit Breaker Upgrades - 4 Pole circuit reaker to 250A, 400A and 630A
- Cooling System
- Coolant heater
- Low coolant temp alarm
- Low coolant level shutdown
- Control Panels
- EMCP 4.2
- Control Panel Options
- Volt free contacts
- Speed adjust potentiometer
- Voltage adjust potentiometer
- Panel mounted audible alarm
- Earth fault (2 wire only)
- Earth leakage (2 wire only)
- Overload shutdown via breaker
- Battery charger
- Emergency stop with key
- Control panel heater
- Enclosures
- Sound attenuated Level 2 enclosure
- Sound attenuated Level 1 (galv)
- Rental pack - CAE rental option only
- CEE form sockets - CAE rental option only
- Socket blanking plate - CAE rental option only
- European Certifications
- Upgrade to STD set for CE
- Fuel System Accessories
- Open set narrow base
- Compact skidbase for open set
- Skidbase for CALG enclosure sets
- Bunded fuel tank
- Low fuel level shutdown
- Low fuel level alarm
- High fuel level alarm
- Global Certifications
- Certification for CIS
- Mounting Options
- Electronic governor
- Battery removal
- External single point lift - enclosure
- Industrial silencer
- Residential siliencer
- Silencer installation kit
- Power Termination
- Circuit breakers, IEC compliant
- Circuit breakers, UL listed
- Special Packing/Inspectons for Shipment
- PGS test report @ 1.0 power factor
- PGS test report @ 0.8 power factor
- General - Accessories / Miscellaneous
- Stone guards / rad trans flange
- Packing case - compact set
- Packing case - canopied set
360° INTERACTIVE
Exterior
Interior
RELATED PRODUCTS
3412C (50 Hz)
power generation diesel hfo
- Height Maximum: 1906 mm75 in
- Length Maximum: 162.4 mm4135 in
- Width Maximum: 1989 mm78.3 in
3512A (50 Hz)
power generation diesel hfo
- Minimum Rating: 1000 kVA
- Maximum Rating: 1400 kVA
- Voltage: 220 to 13800 Volts
3512B (50 Hz)
power generation diesel hfo
- Height Maximum: 2367 mm93.2 in
- Length Maximum: 5637 mm221.9 in
- Width Maximum: 2286 mm90 in
3516 (50 Hz)
power generation diesel hfo
- Height Maximum: 2367 mm93.2 in
- Length Maximum: 5919 mm232.9 in
- Width Maximum: 2286 mm90 in
3516B (50 Hz)
power generation diesel hfo
- Height Maximum: 2367 mm93.2 in
- Length Maximum: 5928 mm233.4 in
- Width Maximum: 2286 mm90 in
3516B DGB™ (50 Hz)
power generation diesel hfo
- Minimum Rating: 1750 kVA
- Maximum Rating: 2275 kVA
- Voltage: 220 to 11000
3516E (50 Hz)
power generation diesel hfo
- Height Maximum: 3476 mm136.9 in
- Length Maximum: 9195 mm362 in
- Width Maximum: 2552 mm100.5 in
C1.5 (50 Hz)
power generation diesel hfo
- Height Maximum: 1054 mm41.5 in
- Length Maximum: 1400 mm55.1 in
- Width Maximum: 620 mm24.4 in
C2.2 (50 Hz)
power generation diesel hfo
- Height Maximum: 1115 mm43.9 in
- Length Maximum: 1500 mm59.1 in
- Width Maximum: 620 mm24.4 in