C18 (50 Hz) power generation diesel hf

  • Height Maximum 1906 mm75 in
  • Length Maximum 4135 mm162.4 in
  • Width Maximum 1989 mm78.3 in

SPECIFICATIONS

  • Height Maximum 1906 mm75 in
  • Length Maximum 4135 mm162.4 in
  • Width Maximum 1989 mm78.3 in
  • Minimum Rating 550 kVA
  • Maximum Rating 715 kVA
  • Voltage 208 to 600 Volts
  • Frequency 50 Hz
  • Speed 1500 or 1800 RPM
  • Emissions Fuel Strategy Low Fuel Consumption, U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 Nonroad Equivalent Emission Standards), China Nonroad III Emission Standards
  • Engine Model C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel
  • Compression Ratio 14.5:1
  • Aspiration Air to Air Aftercooled
  • Governor Type Adem™A4
  • Fuel System Electronic unit injection
  • Bore 145 mm (5.71 in)
  • Displacement 18.13 L (1106.36 in3)
  • Stroke 183 mm (7.2 in)
  • Industry power-generation-diesel-hfo

EQUIPMENT

C18 (50 Hz) Standard Equipment

  • Air Inlet System
    • Light duty air cleaner
    • Aftercooler core
    • Turbocharger
  • Control System
    • EMCP 4.2
  • Cooling
    • Radiator and cooling fan with guard
    • Coolant drain line with valve
    • Fan drive, battery charging alternator drive
    • Caterpillar extended life coolant
  • Exhaust System
    • Stainless steel exhaust flex gaskets, raincap and SAE exhaust flange for customer use; shipped loose
  • Fuel System
    • Standard 8 hour open set fuel tank
  • Generator and Attachments
    • Matched to the performance and output characteristics of Cat engines
    • A frame generator - IP21 protection
    • Integrated Voltage Regulator
    • Integrated Voltage Regulator
    • Power center, IP22
    • Segregated low voltage (AC/DC) wiring panel
    • Mandatory Option circuit breaker, IEC, 3 pole, mounted in power centre
  • Governing System
    • Cat Electronic Governor (ADEM A4)
  • Lube System
    • Lubricating oil
    • Oil drain valves
  • Mounting System
    • Captive linear vibration isolators between base and engine-generator. includes lifting provisions and termination points for coolant and lube oil drain lines
  • Starting/Charging
    • 24 Volt battery with rack and cables
  • General
    • Engine and alternator pre-paint, Caterpillar yellow

C18 (50 Hz) Optional Equipment

  • Air Inlet System
    • Single element air cleaner
    • Dual element air cleaner
  • Circuit Breakers
    • 3 Pole (IEC-100% rated) circuit breakers - Package mounted
    • 4 Pole (IEC-100% rated) circuit breakers - Package mounted
    • 3 Pole (IEC-100% rated) circuit breakers - Motorised
    • 4 Pole (IEC-100% rated) circuit breakers - Motorised
    • Circuit breaker (IEC) auxiliary contacts
    • Shunt trip for IEC breaker
    • Pad-lockable circuit breaker device
    • Power terminal strip
  • Control System
    • EMCP 4.4
    • Volt free contact
    • Local alarm horn
    • Oil temperature displays
    • Protective devices: Earth fault relay - earth leageage ground fault relay - Overload shutdown via breaker - Low fuel level alarm - Low fuel level shutdown - high fuel level alarm - Fuel level sensor
    • Local alarm modules
    • Remote annunciator modules
  • Cooling System
    • Radiator duct flange
    • Low coolant temperature alarm
  • Enclosures
    • Sound attenuated enclosures
  • Exhaust System
    • Engine mounted muffler
    • 10, 25 and 35 end in / end out Mufflers
    • 8 and 10 inch GP flanges
    • 8 and 10 inch elbow kits
    • Manifold and Turbocharger guard
  • Fuel System
    • Integral - Duel wall fuel tank base
    • Manual fuel transfer pump
    • Fuel transfer system
  • Generator and Attachments
    • Ingress protection
    • Permanent magnet excitation
    • Space heaters
    • A frame oversize generator
    • A frame CIP generator
    • LC frame generator
    • LC frame oversize generators
    • LC frame CIP generator
  • Lube System
    • Manual sump pump
  • Starting and Charging
    • 5 Amp battery charger
    • Battery disconnect switch
    • Jacket water heaters

360° INTERACTIVE

Exterior

Interior

RELATED PRODUCTS

3412C (50 Hz) - Power-generation-diesel-hfo

3412C (50 Hz)

power generation diesel hfo

  • Height Maximum: 1906 mm75 in
  • Length Maximum: 162.4 mm4135 in
  • Width Maximum: 1989 mm78.3 in
Get a quote
3512A (50 Hz) - Power-generation-diesel-hfo

3512A (50 Hz)

power generation diesel hfo

  • Minimum Rating: 1000 kVA
  • Maximum Rating: 1400 kVA
  • Voltage: 220 to 13800 Volts
Get a quote
3512B (50 Hz) - Power-generation-diesel-hfo

3512B (50 Hz)

power generation diesel hfo

  • Height Maximum: 2367 mm93.2 in
  • Length Maximum: 5637 mm221.9 in
  • Width Maximum: 2286 mm90 in
Get a quote
3516 (50 Hz) - Power-generation-diesel-hfo

3516 (50 Hz)

power generation diesel hfo

  • Height Maximum: 2367 mm93.2 in
  • Length Maximum: 5919 mm232.9 in
  • Width Maximum: 2286 mm90 in
Get a quote
3516B (50 Hz) - Power-generation-diesel-hfo

3516B (50 Hz)

power generation diesel hfo

  • Height Maximum: 2367 mm93.2 in
  • Length Maximum: 5928 mm233.4 in
  • Width Maximum: 2286 mm90 in
Get a quote
3516B DGB™ (50 Hz) - Power-generation-diesel-hfo

3516B DGB™ (50 Hz)

power generation diesel hfo

  • Minimum Rating: 1750 kVA
  • Maximum Rating: 2275 kVA
  • Voltage: 220 to 11000
Get a quote
3516E (50 Hz) - Power-generation-diesel-hfo

3516E (50 Hz)

power generation diesel hfo

  • Height Maximum: 3476 mm136.9 in
  • Length Maximum: 9195 mm362 in
  • Width Maximum: 2552 mm100.5 in
Get a quote
C1.5 (50 Hz) - Power-generation-diesel-hfo

C1.5 (50 Hz)

power generation diesel hfo

  • Height Maximum: 1054 mm41.5 in
  • Length Maximum: 1400 mm55.1 in
  • Width Maximum: 620 mm24.4 in
Get a quote
C2.2 (50 Hz) - Power-generation-diesel-hfo

C2.2 (50 Hz)

power generation diesel hfo

  • Height Maximum: 1115 mm43.9 in
  • Length Maximum: 1500 mm59.1 in
  • Width Maximum: 620 mm24.4 in