Specifications

C175-16

Specifications

Minimum Rating1833 ekW2619 kV·A
Maximum Rating2660 ekW3325 kV·A
EmissionsAvailable in IMO Tier II/ EPA Marine Tier 2 configurations
AspirationTurbocharged/2-stage aftercooled
Bore175 mm6.89 in
Displacement85 l5167 in³
Engine ControlDual ADEM™ A4
Fuel SystemCommon Rail/EUI™
Generator Set ControlMPD 3.0 / Cat® Alarm and Protection System
Oil Change Interval1000 h1000 h
Stroke220 mm8.66 in
Weight24312 kg53599 lb
Height50 Hz - 2928 (115 in) / 60 Hz - 2916 mm ( 115 in)
Length50 Hz - 6782 mm (267 in) / 60 Hz - 6742 mm (265 in)
Width50 Hz - 2413 mm (95 in) / 60 Hz - 2125 mm (84 in)
Cooling System - Engine77 l92 gal (US)
Lube Oil System - Refill946 l250 gal (US)
Speed1200/1500/1800 rpm

C175-16 Standard Equipment

  • Air Inlet System
    • Dual turbochargers
    • Corrosion-resistant aftercooler core
    • Air cleaners — single or dual element
  • Exhaust System
    • Dry exhaust manifolds with thermo-laminated heat shields
    • Dual turbochargers with water-cooled bearings and thermo-laminated heat shields
    • Vertical exhaust outlet
    • Flange and exhaust expanders
  • Cooling System
    • Separate-circuit-aftercooler (SCAC) and jacket water (JW) circuit cooling system
    • Gear-driven centrifugal pumps, one for each circuit
    • SCAC electronic thermostat, outlet-controlled with aftercooler inlet temperature sensing
    • JW electronic thermostat, outlet-controlled with outlet temperature sensing
    • Engine oil cooler in JW circuit
  • Fuel System
    • Cat common rail high-pressure fuel system with electronically controlled unit injectors
    • Duplex primary fuel filter with water separator
    • Duplex secondary/tertiary fuel filters
    • Electric fuel priming pump
    • Gear-driven low pressure transfer pump
    • Gear-driven high pressure transfer pump
    • Double-walled high pressure fuel lines
    • Fuel pressure, temperature, and leak detection sensors
  • Lubrication System
    • Engine-driven, gear-type oil pump
    • Integral lube oil cooler
    • Front-mounted oil drain lines and valve
    • Oil sampling valve
    • Filler and dipstick
    • Four-canister simplex oil filter
    • Prelube pump — electric, air, or custom
    • Fumes disposal with crankcase breathers
    • Crankcase explosion relief valves
  • Engine Control and Protection
    • Dual ADEM A4 engine control unit (ECU) for redundancy
    • Software monitors engine parameters and performs alarm, derate, and shutdown functions
    • Rigid wiring harness
    • Marine Power Display 3.0 (MPD 3.0)
  • Mounting
    • Inner-outer base with vibration isolators
  • Generator
    • Kato brushless permanent magnet 6P6.6-3200 HR
    • 2-bearing, close-coupled arrangement
    • 60 Hz, 600V, 0.7 PF
    • UL/CSA listed, IP23
  • Flywheel and Coupling
    • Flywheel housing, SAE No. 00
    • Flywheel, SAE No. 00
    • ABS certified, non-certified, or custom-coupling and coupling mounting
    • Free-standing or close-coupled generator set arrangements
  • Starting System
    • Turbine air starter or
    • Dual electric starting motors or
    • Air and electric starting motors (redundant)
  • General
    • Power distribution box — 24V or custom
    • 20A battery charger
    • Cat yellow paint
    • Offshore oil field sub-base
    • Integral spring isolators with limit stop
    • Lift provisions on base
    • Oil drain extension
    • Engine length drip pan with drain
    • Torsional dampened driveline couplings

C175-16 Optional Equipment

  • Air Inlet System
    • Air cleaner service indicator
  • Cooling System
    • 9 kW, 240V, 60 hz jacket water heater
    • Custom jacket water heater
  • Fuel System
    • Four canister duplex oil filter
  • Engine Control and Protection
    • Cat Alarm and Protection System
    • Communication module PL1000T/E
    • Direct-rack control
    • Thermocouples
    • Metal particle detector
    • SOLAS spray shielding
  • Mounting
    • Custom I-beam base with vibration isolators
  • Generator
    • Custom generator
  • General
    • TVA report
    • Special tests
    • Project-specific installation drawings
    • P&ID-electrical drawings
    • Spare parts kit
    • Barring group
    • Engine lifting group
    • Custom generators and radiators

Exterior

Specifications

Minimum Rating1833 ekW2619 kV·A
Maximum Rating2660 ekW3325 kV·A
EmissionsAvailable in IMO Tier II/ EPA Marine Tier 2 configurations
AspirationTurbocharged/2-stage aftercooled
Bore175 mm6.89 in
Displacement85 l5167 in³
Engine ControlDual ADEM™ A4
Fuel SystemCommon Rail/EUI™
Generator Set ControlMPD 3.0 / Cat® Alarm and Protection System
Oil Change Interval1000 h1000 h
Stroke220 mm8.66 in
Weight24312 kg53599 lb
Height50 Hz - 2928 (115 in) / 60 Hz - 2916 mm ( 115 in)
Length50 Hz - 6782 mm (267 in) / 60 Hz - 6742 mm (265 in)
Width50 Hz - 2413 mm (95 in) / 60 Hz - 2125 mm (84 in)
Cooling System - Engine77 l92 gal (US)
Lube Oil System - Refill946 l250 gal (US)
Speed1200/1500/1800 rpm

Equipment

C175-16 Standard Equipment

  • Air Inlet System
    • Dual turbochargers
    • Corrosion-resistant aftercooler core
    • Air cleaners — single or dual element
  • Exhaust System
    • Dry exhaust manifolds with thermo-laminated heat shields
    • Dual turbochargers with water-cooled bearings and thermo-laminated heat shields
    • Vertical exhaust outlet
    • Flange and exhaust expanders
  • Cooling System
    • Separate-circuit-aftercooler (SCAC) and jacket water (JW) circuit cooling system
    • Gear-driven centrifugal pumps, one for each circuit
    • SCAC electronic thermostat, outlet-controlled with aftercooler inlet temperature sensing
    • JW electronic thermostat, outlet-controlled with outlet temperature sensing
    • Engine oil cooler in JW circuit
  • Fuel System
    • Cat common rail high-pressure fuel system with electronically controlled unit injectors
    • Duplex primary fuel filter with water separator
    • Duplex secondary/tertiary fuel filters
    • Electric fuel priming pump
    • Gear-driven low pressure transfer pump
    • Gear-driven high pressure transfer pump
    • Double-walled high pressure fuel lines
    • Fuel pressure, temperature, and leak detection sensors
  • Lubrication System
    • Engine-driven, gear-type oil pump
    • Integral lube oil cooler
    • Front-mounted oil drain lines and valve
    • Oil sampling valve
    • Filler and dipstick
    • Four-canister simplex oil filter
    • Prelube pump — electric, air, or custom
    • Fumes disposal with crankcase breathers
    • Crankcase explosion relief valves
  • Engine Control and Protection
    • Dual ADEM A4 engine control unit (ECU) for redundancy
    • Software monitors engine parameters and performs alarm, derate, and shutdown functions
    • Rigid wiring harness
    • Marine Power Display 3.0 (MPD 3.0)
  • Mounting
    • Inner-outer base with vibration isolators
  • Generator
    • Kato brushless permanent magnet 6P6.6-3200 HR
    • 2-bearing, close-coupled arrangement
    • 60 Hz, 600V, 0.7 PF
    • UL/CSA listed, IP23
  • Flywheel and Coupling
    • Flywheel housing, SAE No. 00
    • Flywheel, SAE No. 00
    • ABS certified, non-certified, or custom-coupling and coupling mounting
    • Free-standing or close-coupled generator set arrangements
  • Starting System
    • Turbine air starter or
    • Dual electric starting motors or
    • Air and electric starting motors (redundant)
  • General
    • Power distribution box — 24V or custom
    • 20A battery charger
    • Cat yellow paint
    • Offshore oil field sub-base
    • Integral spring isolators with limit stop
    • Lift provisions on base
    • Oil drain extension
    • Engine length drip pan with drain
    • Torsional dampened driveline couplings

C175-16 Optional Equipment

  • Air Inlet System
    • Air cleaner service indicator
  • Cooling System
    • 9 kW, 240V, 60 hz jacket water heater
    • Custom jacket water heater
  • Fuel System
    • Four canister duplex oil filter
  • Engine Control and Protection
    • Cat Alarm and Protection System
    • Communication module PL1000T/E
    • Direct-rack control
    • Thermocouples
    • Metal particle detector
    • SOLAS spray shielding
  • Mounting
    • Custom I-beam base with vibration isolators
  • Generator
    • Custom generator
  • General
    • TVA report
    • Special tests
    • Project-specific installation drawings
    • P&ID-electrical drawings
    • Spare parts kit
    • Barring group
    • Engine lifting group
    • Custom generators and radiators

360° Interactive

Exterior

Related Products